NDB2LE-40
656The NDB2LE-40 series of residual current action circuit breakers provide the ground leakage, direct or indirect electric shock by human body and other faults protection, wh...
Посмотреть подробности
●Protection against short circuit
●Protection against overload
●earth leakage Protection
●Isolation
NDB2LE-63 series residual current unit clipped onto the right side of NDB2-63 series MCBs to protection against earth leakage faults ,which is used in low voltage electrical distribution system in industry, real estate, power, telecom and construction field.
2.Model:

3.Main technical parameters
Electrical parameters
○ Rated working voltage (Ue):AC230/240V(1P+N、2P) AC380/400/415V(3P、3P+N、4P)
○ Rated current (In): 1A, 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
○ GB 16917.1、IEC 61009-1、GB16917.22、IEC61009-2-2
4.Working conditions
5.Tripping curves (ambient temperature 30℃)

B Curve

C Curve

D Curve
6.Outline dimensions and installation

1P+N

2P

3P

3P+N

4P
7.Mounting
Modularized structure, can be easily installed in TH35mm×7.5 Standard DIN rail.
8.Packaging and storage
8.1Maximum packing quantity
1N-pole: 4 pieces in a box, 12 boxes in an overwrap carton. 2-pole: 3 pieces in a box, 12 boxes in an overwrap carton. 3-pole: 2 pieces in a box, 12 boxes in an overwrap carton. 3N-pole: 1 pieces in a box, 12 boxes in an overwrap carton. 4-pole: 1 pieces in a box, 12 boxes in an overwrap carton.
8.2 The products should be stored in the warehouse where there is ventilation. The relative humidity there should not exceed 80%, and the ambient temperature there is between
-30℃ to +70℃. In addition, there should not be acidic, alkaline and corrosive gas in the air.
The products should not be deposited more than 3 years in the above mentioned conditions since the producing date.
9.Accessories
●MX+OF2 shunt trip release :Installed on the left hand of NDB2LE- 63 series RCBOs, remote control of the circuit breaker’s tripping;
10.Notices
The NDB2LE-40 series of residual current action circuit breakers provide the ground leakage, direct or indirect electric shock by human body and other faults protection, wh...
Посмотреть подробности1. Applicable Scope and Purpose of Circuit Breaker The NDM2L-250 molded case circuit breaker with the residual current protection (hereinafter referred to as circuit breaker) applies to infrequent switching of circuits with the AC 50/60H...
Посмотреть подробности1、Applicable scope and purpose Short circuit protection Overload protection Isolation Earth leakage NDB2LM-63 series residual current protection module is used for protecting earth leakage, director indirect electric-shock on body and a...
Посмотреть подробности1、Applicable scope and purpose ●Short -circuit protection ●Over-load protection ●Control ●Isolation ●DC system protection NDB2Z-63 dedicated to the low voltage power distribution system of industrial, buildings, energy communi...
Посмотреть подробности
Отправить запрос о продукте
Мы свяжемся с вами в течение 24 часов